✨ New Arrivals Just Dropped!Explore
Product image 1
Product image 2
Product image 3
Product image 4
Product image 5
Product image 6
Product image 7
Product image 8
Product image 9
Product image 10
Product image 11
Product image 12
Product image 13
Product image 14
HomeStore

Commercial Shutter Fan

Commercial Shutter Fan

This ES Series Fan is a commercial-quality exhaust fan for the hobby grower. It has a heavy-duty design made of metal - no plastic parts! The fully enclosed motor is thermally protected and designed for continuous duty. Each commercial fan includes an exterior aluminum shutter that opens fully for maximum CFM output. Outdoor air is drawn in through a motorized shutter and hot air is exhausted through this motorized shutter fan. An optional 10-foot grounded cord is available for each model.

These industrial fans keep fresh air flowing through a greenhouse, which controls temperatures, lowers the humidity and reduce the risk of fungal distance. You can also use it as a garage exhaust fan. We offer commercial shutter fans in size from 10 to 30 inches with motors ranging from 1/10 to 1/2 HP - see the tables below for their CFM ratings, power requirements, speed options and more. They’re covered by a full two-year motor warranty and our 100% customer satisfaction guarantee.

ES Series Greenhouse Commercial Fan Features:

  • Smooth and quiet operation
  • Ships totally assembled
  • Balanced 3 bladed aluminum prop with a zinc plated steel hub
  • Chrome guard allows for easy cleaning and meets OSHA 1910.212(a)(5) requirements to mount at any height on inlet side of fan.
  • High-efficiency aluminum shutters with tie bar to eliminate shutter flapping and opening on windy days.
  • Direct drive high-efficiency motors are totally enclosed with completely sealed ball bearings, making them maintenance-free.
  • Motor is covered by a full two-year warranty.

Specifications

Model Size HP Spd Volts Amps HZ Phs Spd RPM Rough Opening
VES10C 10" 1/8 3 115 0.9 60 1 3 1,737 12 1/2" x 12 1/2"
VES12 12" 1/10 S/Var* 115/230 1.42/0/5 60/50 1 S/V* 1,710 12 1/2" x 12 1/2"
VES12C 12" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,710 12 1/2" x 12 1/2"
VES161 16" 1/10 S/Var* 115/230 1.42/.077 60/50 1 S/V* 1,727 16 1/2" x 16 1/2"
VES161C 16" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,727 16 1/2" x 16 1/2"
VES201 20" 1/10 S/Var* 115/230 1.42/.077 60/50 1 S/V* 1,720 20 1/2" x 20 1/2"
VES201C 20" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,720 20 1/2" x 20 1/2"
VES20 20" 1/3 S/Var* 115/230 3.8/1.9 60 1 S/V* 1,704 20 1/2" x 20 1/2"
VES20C 20" 1/3 S/Var* 115 3.8 60 1 S/V* 1,704 20 1/2" x 20 1/2"
VES24 24" 1/2 S/Var* 115/230 4.8/2.4 60/50 1 S/V* 1,672 24 1/2" x 24 1/2"
VES24C 24" 1/2 S/Var* 115 4.8 60/50 1 S/V* 1,672 24 1/2" x 24 1/2"
VES30 30" 1/2 1 115/230 6.2/3.1 60/50 1 1 858 30 1/2" x 30 1/2"
VES30C 30" 1/2 1 115 6.2 60/50 1 1 858 30 1/2" x 30 1/2"


Model Size @0.0" SP
CFM/Watt
@0.05" SP
CFM/Watt
@0.10" SP
CFM/Watt
@0.15" SP
CFM/Watt
VES10C 10" 683/8.3 569/6.8 464/5.5 346/4.0
VES12 12" 1,006/11.9 898/10.5 748/8.7 574/6.6
VES12C 12" 1,006/11.9 898/10.5 748/8.7 574/6.6
VES161 16" 1,438/14.4 1,289/12.6 1,034/10.1 683/6.6
VES161C 16" 1,438/14.4 1,289/12.6 1,034/10.1 683/6.6
VES201 20" 1,644/16.1 1,389/13.3 941/9.0 714/6.5
VES201C 20" 1,644/16.1 1,389/13.3 941/9.0 714/6.5
VES20 20" 3,126/10.8 2,875/9.7 2,697/8.9 2,540/8.3
VES20C 20" 3,126/10.8 2,875/9.7 2,697/8.9 2,540/8.3
VES24 24" 4,548/9.8 4,124/8.7 3,849/7.9 3,629/7.4
VES24C 24" 4,548/9.8 4,124/8.7 3,849/7.9 3,629/7.4
VES30 30" 6,785/13.3 6,300/12.1 5,801/11 5,123/9.7
VES30C 30" 6,785/13.3 6,300/12.1 5,801/11 5,123/9.7

* Variable speed fans require separate variable speed control to adjust fan speed.

Additional Information

Manual

Commercial Shutter Fan - ES SHUTTER FAN
Note: The wiring diagram for the shutter fan is located directly on the motor housing.

Thermostat

How-to-Wire for Heating or Cooling

How Do I Size My Fans and Shutters System?

1. The first thing that you need to determine is the amount of air required. This is stated in CFM (Cubic Feet of Air per Minute).

2. Use the following formula to determine the CFM required for your greenhouse:
CFM = Length x Width x Height
Example: A greenhouse 12' wide x 24' long x 12' high requires 3,456 CFM (12 x 24 x 12 = 3,456))

3. Reference the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters.


Select Size
Select Cord
From $62.65

Original: $179.00

-65%
Commercial Shutter Fan

$179.00

$62.65

Product Information

Shipping & Returns

Description

This ES Series Fan is a commercial-quality exhaust fan for the hobby grower. It has a heavy-duty design made of metal - no plastic parts! The fully enclosed motor is thermally protected and designed for continuous duty. Each commercial fan includes an exterior aluminum shutter that opens fully for maximum CFM output. Outdoor air is drawn in through a motorized shutter and hot air is exhausted through this motorized shutter fan. An optional 10-foot grounded cord is available for each model.

These industrial fans keep fresh air flowing through a greenhouse, which controls temperatures, lowers the humidity and reduce the risk of fungal distance. You can also use it as a garage exhaust fan. We offer commercial shutter fans in size from 10 to 30 inches with motors ranging from 1/10 to 1/2 HP - see the tables below for their CFM ratings, power requirements, speed options and more. They’re covered by a full two-year motor warranty and our 100% customer satisfaction guarantee.

ES Series Greenhouse Commercial Fan Features:

  • Smooth and quiet operation
  • Ships totally assembled
  • Balanced 3 bladed aluminum prop with a zinc plated steel hub
  • Chrome guard allows for easy cleaning and meets OSHA 1910.212(a)(5) requirements to mount at any height on inlet side of fan.
  • High-efficiency aluminum shutters with tie bar to eliminate shutter flapping and opening on windy days.
  • Direct drive high-efficiency motors are totally enclosed with completely sealed ball bearings, making them maintenance-free.
  • Motor is covered by a full two-year warranty.

Specifications

Model Size HP Spd Volts Amps HZ Phs Spd RPM Rough Opening
VES10C 10" 1/8 3 115 0.9 60 1 3 1,737 12 1/2" x 12 1/2"
VES12 12" 1/10 S/Var* 115/230 1.42/0/5 60/50 1 S/V* 1,710 12 1/2" x 12 1/2"
VES12C 12" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,710 12 1/2" x 12 1/2"
VES161 16" 1/10 S/Var* 115/230 1.42/.077 60/50 1 S/V* 1,727 16 1/2" x 16 1/2"
VES161C 16" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,727 16 1/2" x 16 1/2"
VES201 20" 1/10 S/Var* 115/230 1.42/.077 60/50 1 S/V* 1,720 20 1/2" x 20 1/2"
VES201C 20" 1/10 S/Var* 115 1.42 60/50 1 S/V* 1,720 20 1/2" x 20 1/2"
VES20 20" 1/3 S/Var* 115/230 3.8/1.9 60 1 S/V* 1,704 20 1/2" x 20 1/2"
VES20C 20" 1/3 S/Var* 115 3.8 60 1 S/V* 1,704 20 1/2" x 20 1/2"
VES24 24" 1/2 S/Var* 115/230 4.8/2.4 60/50 1 S/V* 1,672 24 1/2" x 24 1/2"
VES24C 24" 1/2 S/Var* 115 4.8 60/50 1 S/V* 1,672 24 1/2" x 24 1/2"
VES30 30" 1/2 1 115/230 6.2/3.1 60/50 1 1 858 30 1/2" x 30 1/2"
VES30C 30" 1/2 1 115 6.2 60/50 1 1 858 30 1/2" x 30 1/2"


Model Size @0.0" SP
CFM/Watt
@0.05" SP
CFM/Watt
@0.10" SP
CFM/Watt
@0.15" SP
CFM/Watt
VES10C 10" 683/8.3 569/6.8 464/5.5 346/4.0
VES12 12" 1,006/11.9 898/10.5 748/8.7 574/6.6
VES12C 12" 1,006/11.9 898/10.5 748/8.7 574/6.6
VES161 16" 1,438/14.4 1,289/12.6 1,034/10.1 683/6.6
VES161C 16" 1,438/14.4 1,289/12.6 1,034/10.1 683/6.6
VES201 20" 1,644/16.1 1,389/13.3 941/9.0 714/6.5
VES201C 20" 1,644/16.1 1,389/13.3 941/9.0 714/6.5
VES20 20" 3,126/10.8 2,875/9.7 2,697/8.9 2,540/8.3
VES20C 20" 3,126/10.8 2,875/9.7 2,697/8.9 2,540/8.3
VES24 24" 4,548/9.8 4,124/8.7 3,849/7.9 3,629/7.4
VES24C 24" 4,548/9.8 4,124/8.7 3,849/7.9 3,629/7.4
VES30 30" 6,785/13.3 6,300/12.1 5,801/11 5,123/9.7
VES30C 30" 6,785/13.3 6,300/12.1 5,801/11 5,123/9.7

* Variable speed fans require separate variable speed control to adjust fan speed.

Additional Information

Manual

Commercial Shutter Fan - ES SHUTTER FAN
Note: The wiring diagram for the shutter fan is located directly on the motor housing.

Thermostat

How-to-Wire for Heating or Cooling

How Do I Size My Fans and Shutters System?

1. The first thing that you need to determine is the amount of air required. This is stated in CFM (Cubic Feet of Air per Minute).

2. Use the following formula to determine the CFM required for your greenhouse:
CFM = Length x Width x Height
Example: A greenhouse 12' wide x 24' long x 12' high requires 3,456 CFM (12 x 24 x 12 = 3,456))

3. Reference the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters.